Industrial steam boiler UNIVERSAL ZFR, ZFR-X

For very high steam or heat requirements, boilers are available in the output range of 18,000 to 55,000 kg/h.

Industrial steam boiler UNIVERSAL ZFR, ZFR-X

The UNIVERSAL ZFR two-tube boiler is a large-volume boiler based on triple-path technology with two fire tubes and completely separate flue gas paths. You will find it wherever a high supply of steam and heat is required.

The two-tube furnace and flue tube boiler is, with its separate flue paths, also suitable for single-fired operation. The three-path principle with the flooded gas changeover chamber has been patented by Bosch. Our boilers can be easily supplemented with our economizer and superheater modules. The dimensions of the fire tubes, flue tubes, water chamber and steam chamber are thermodynamically optimized. Radiation and convection surfaces produce a special dynamic in combination with the possibility of operating on a fire tube. A heat transfer system ensures that the heat supplied by the fuel is quickly converted into steam without any strain on the boiler.

TypeUNIVERSAL ZFRUNIVERSAL ZFR-X
Transfert de chaleurVapeur saturée haute pressionVapeur saturée haute pression
ConstructionChaudière à tube foyer à triple parcoursChaudière à tube foyer à triple parcours
Puissance18 000 à 55 000 kg/h18 000 à 55 000 kg/h
Limite de surpression [bar]jusqu'à 30 barsjusqu'à 30 bars
Température maxi.jusqu'à 235 °Cjusqu'à 300 °C
CombustibleFuel, gazFuel, gaz


The UNIVERSAL ZFR series is also perfectly suited for cascading several boilers. Important fields of application are companies in all economic sectors, production industries and public services.


  • Intuitive boiler control on a PLC basis with transparency of operational data
  • High efficiency thanks to triple-path technology, integrated economizer and thermal insulation
  • High pressure consistency and steam quality even with highly fluctuating steam requirements
  • SUCcess automatic start-up, provisioning and departure device
  • Suitable for many burners
  • Low-emission combustion thanks to state-of-the-art combustion systems and the best boiler/burner combination
  • Easy to maintain - easy to inspect on both the flue and water sides
  • Robust, reliable and incomparably durable
  • Approved according to the European Pressure Equipment Directive, usable worldwide
  • Extremely high control range with one-tube operation
  • Easy to upgrade (integrated modular technology)
  • Easy commissioning thanks to pre-configured boiler control
  • Easy wiring on site thanks to plug-in connections

Our patent for the three-path system is the basis for the lasting success of this series. The ability of the fireplaces to operate in parallel or individually without restriction is not only achieve by the stability of the gas side separation. In order to neutralize the thermal stresses with one-fire operation, a special construction design is essential to maintain long-term reliability. The furnace tubes are solidly welded and installed in the front and rear bottoms. A stabilizing, water-through wall attached to the rear bottom separates the flooded gas reversal chamber. The water circulation and heat transport are effectively boosted by conductive profiles at the boiler base and accelerate by sweeping gases between the fire tubes and the flue tubes.

 

Thanks to the TÜV-approved single-burner operation, fully automatic operation with one or two burners is possible. The use of different fuels on each of the two burners is not a problem. The control range is doubled and any low-load operation benefits from optimum burner efficiency.

 

If overheated steam is required rather than saturated steam, a overheated module can be use on the front reversing chamber. A bypass valve continuously regulates the temperature of the overheated steam over a wide operating range. The smoke tube bundles remain easily accessible through the front door.

  • Modular system, controlled on the flue gas side. No water injection required for superheated steam temperature control
  • Easy maintenance and installation - easy cleaning of the second and third boiler path
  • Long service life due to low thermal load of the entire overheater body

 


All of our high volume boilers with accessories are available as fully functional units. Standard equipment includes boiler pressure vessel, control and safety technology, burner unit, feed pump module, connection box and control cabinet including BCO boiler control.

Base equipment

Variable equipment according to the customer's wishes

Associated boiler room elements


  • Water conditioning module WTM

  • Water service module WSM

  • Condensate module CSM

  • Blowdown, expansion and cooling module BEM

  • Pump module PM

  • Expansion, heat recovery and blowdown module EHB

  • Steam Cooler VC

  • Water analyzer WA

  • Expansion and heat recovery module EHM

  • Gas control module GRM

  • Oil circulation module OCM

  • Oil supply module OSM

  • Oil preheating module OPM

  • Plant management system SCO

  • Flue gas heat exchanger ECO 1 (individual installation)

  • Flue gas heat exchanger ECO 6 (individual installation)